IEEE Std 446-1995, IEEE Recommended Practice for Emergency...

IEEE Std 446-1995, IEEE Recommended Practice for Emergency and Standby Power Systems for Industrial and Commerical Applications

Inst of Electrical & Electronics Engineers
0 / 5.0
0 comments
Насколько вам понравилась эта книга?
Какого качества скаченный файл?
Скачайте книгу, чтобы оценить ее качество
Какого качества скаченные файлы?
Introduction (This introduction is not a part of IEEE Std 446-1995, IEEE Recommended Practice for Emergency and Standby Power Systems for Industrial and Commercial Applications.) In 1968 the Industrial and Commercial Power Systems Committee within the Industry and General Applications Group of the Institute of Electrical and Electronics Engineers recognized that a need existed for a publication that would provide guidance to industrial users and suppliers of emergency and standby power systems. The nature of electric power failures, interruptions, and their duration covers a range in time from microseconds to days. Voltage excursions occur within a range from 20 times normal (or more) to a complete absence of voltage. Frequency excursions can vary as widely in many forms, from harmonics to direct current. These variables occur due to a multitude of conditions both in the power system ahead of the user’s service entrance and following the service entrance within the user’s area of distribution. Such elements as lightning, automobiles striking power poles, ice storms, tornadoes, switching to alternate lines, and equipment failure are but a few of the causes of interruptions in the electric power supply ahead of the service entrance. Within the user’s area of distribution are such elements as short and open circuits, undersized feeders, equipment failures, operator errors, temporary overloads, single-phasing unbalanced feeders, fire, switching, and many other causes of power interruption or failure. In the past the demand for reliable electric power was less critical. If power was completely interrupted too often, another source was found. If voltage varied enough to cause a problem, a regulator or a larger conductor was installed. As processes, controls, and instrumentation became more sophisticated and interlocked, the demand developed to shorten the length of outages. Increased safety standards for people required emergency and exit lighting. Many factories added…
Категории:
Год:
1996
Издательство:
Inst of Electrical & Electronics Engineers
Язык:
english
Страницы:
309
ISBN 10:
1559375981
ISBN 13:
9781559375986
Файл:
PDF, 3.39 MB
IPFS:
CID , CID Blake2b
english, 1996
Читать Онлайн
Выполняется конвертация в
Конвертация в не удалась

Ключевые слова